Parker Denison P24P3R1E5A2A00 Hydraulic Pump – 023-82666-0

Order No. 023-82666-0 identifies this Parker Denison hydraulic pump in the Gold Cup Pump Series; the source model code is P24P3R1E5A2A00.

Parker Hydraulic Pumps Gold Cup Pump Series
BrandParker
Order No023-82666-0
ModelP24P3R1E5A2A00
Product NameParker Denison P24P3R1E5A2A00 Hydraulic Pump – 023-82666-0
Product TypeHydraulic Pump
Alternate Model / Model 1P24P 3R1E 5A2 A00
SeriesGold Cup Pump Series
Availability / Lead Time

Product Details

Product Overview

  • Alternate code P24P 3R1E 5A2 A00 is shown as an additional identification reference. It does not by itself confirm interchangeability.

Back to Gold Cup Pump Series

Product Identification

BrandParker
SeriesGold Cup Pump Series
Order No023-82666-0
ModelP24P3R1E5A2A00
Alternate modelsP24P 3R1E 5A2 A00
Also searched asP24P 3R1E 5A2 A00 / 023-82666-0 / 023826660 / P24P3R1E5A2A00

Product Classification

Product typeHydraulic Pump
Documented displacement403 cm3/rev

Series-specific model code

Original model: P24P3R1E5A2A00

Code coverage: Evidence-supported meanings shown. Contact us to confirm unresolved selections.

Evidence profile: Gold Cup pump field-by-field ordering-code profile (manual-evidence revision 6)

Code segmentEvidence-bound meaning
P Unit: pump.
24 Documented displacement: 403 cm3/rev.
P Type: Variable displacement, closed circuit pump.
3 Shaft: splined SAE with mechanical seal.
R Rotation: Clockwise (pump).
1 Seals: nitrile (Buna-N).
E Design code: E (assigned by manufacturer).
5A Primary control: electrohydraulic stroker with adjustable maximum volume stops.
2 Secondary control: volume indicator.
A Control location: primary control on Port A side.
00 Control feature: with deadband.
Internal pump Contact us to confirm.

The parser uses longest-match field boundaries for displacement, optional efficiency, shaft and compact controls. Documented selected values are shown individually; unknown, truncated and extra selections remain visible and show Contact us to confirm. Omitted optional fields are not presented as selected defaults.

Availability

Inquiry Only.

FAQ

Product FAQ

Is this the right record for my order number?

Use this record when the Order No or model code matches your nameplate. Send photos if the code is incomplete or written differently.

Can an alternate model code be used?

Yes, but the quote should still be checked against the primary order number and nameplate photo.

What should I send for quote review?

Send the complete order number, complete model code, nameplate photo when available, and required quantity.